AUTOMATED TEST SOFTWARE FOR POWER SUPPLY/ELECTRONIC LOAD
- Data logging securely in real-time
- Easy to use in simple settings
- Group and individual control of 512 instruments
Easily Generating Multiple Test Sequences
Multifunctional and easy sequence controls for testing solutions
PSS2en is dedicated software that enables multiple and simple sequence programming of various power supplies, electronic loads, and digital controllers for power supplies manufactured by Matsusada Precision. Various units and different types of power supply and electronic load combinations can be linked and controlled, making it suitable for all-around testing.
It is perfect for aging tests of electronic components, accelerated life tests, burn-in tests, withstand voltage tests, dielectric breakdown tests, endurance tests, intermittent/continuous operation tests, and various simulation tests for automotive electrical components.
APPLICATIONS
Destructive testing of electronic components (capacitors).
PSS2en can load voltage with the ramp waveform control, thereby enabling breakdown voltage measurement of components. PSS2en supports our programmable DC power supplies and high-voltage power supplies.
Thermal cycle testing of rechargeable batteries, connectors, etc.
PSS2en creates sequence patterns that simulate actual use and charges high currents with constant intervals to perform thermal cycling testing.
The testing is available in combination with our DC power supplies and electronic loads.
Endurance testing of products and components in conjunction with temperature chambers
While controlling the power supply with sequence patterns, PSS2en is available for the temperature control and monitoring of the temperature chamber.
PSS2en can work together with power supplies, loads, and ESPEC's temperature chambers.
Besides, the PSS2en can be used for a wide range of applications:
voltage fluctuation tests, high power electrical tests, withstand tests, highly accelerated life tests, migration tests, insulation resistance tests, and measurement of insulation aging, etc.
FEATURES
- Simple settings of different operation modes enable various sequence programming.
- Monitoring function allows real-time storage of log data.
- Group control on 512 units and individual control by sequence programming.
- By combining environmental testing with ESPEC's temperature chambers, the temperature and humidity of the load can be changed continuously.
- Group control on multiple types of power supplies and electronic loads is available in the single application software.
- LAN, USB (TMC), and RS-485 interface are ready, in addition to RS-232C. (available only with -LMi option for multiple-digital interface)
- Remotely and direct controlling of output voltage/current values of power supplies is available.
Models
Model No. of PSS2en series | Models supported | PSS2en-ALL | Models available with PSS2en control |
---|
Model No. of PSS2en series | Models supported |
---|---|
PSS2en-DCPS | Following Models are all supported. |
PSS2en-R4K36 | R4K-36 series |
PSS2en-R4K80 | R4K-80 series |
PSS2en-RK80 | RK-80 series *1 |
PSS2en-R4G | R4G series *1 |
PSS2en-R4GT | R4GT series *1 |
PSS2en-RK | RK series |
PSS2en-RKT | RKT series |
PSS2en-RE | RE series *1 |
PSS2en-REK | REK series |
PSS2en-REH | REH series *1 |
PSS2en-REKJ | REKJ series |
PSS2en-TB | TB series |
PSS2en-VOL | VOL series |
PSS2en-PVCE | PVCE series |
Model No. of PSS2en series | Models supported |
---|---|
PSS2en-DCEL | Following Models are all supported. |
PSS2en-EHD | EHD series |
PSS2en-EGS | EGS series |
PSS2en-EGD | EGD series |
PSS2en-EZD | EZD series |
Model No. of PSS2en series | Models supported |
---|---|
PSS2en-ACPS | Following Models are all supported. |
PSS2en-DRJ | DRJ series *1 |
PSS2en-DRS | DRS series |
PSS2en-DRK *2 | DRK series *1 |
Model No. of PSS2en series | Models supported |
---|---|
PSS2en-HVPS | Following Models are all supported. |
PSS2en-EPR | EPR series *1 |
PSS2en-AES *2 | AESS series |
Model No. of PSS2en series | Models supported |
---|---|
PSS2en-AMP | Following Models are all supported. |
PSS2en-DOPF | DOPF series *1 |
PSS2en-DOSF | DOSF series *1 |
PSS2en-DOEF | DOEF series *1 |
PSS2en-DOKF | DOKF series |
PSS2en-DJOPF | DJOPF series *1 |
Model No. of PSS2en series | Models supported |
---|---|
PSS2en-CO | Following Models are all supported. |
PSS2en-CORG | RG series *3 |
PSS2en-COHV | ES series *1 *3 |
AU series *3 | |
AUH series *3 | |
AE series *1 *3 | |
AK/AKP series *1 |
Model No. of PSS2en series | Models supported |
---|---|
PSS2en-COMS | Whole power supplies intervened to controller CO-MS *4 |
- For the PSS2en series, it is possible to order in combination with them. (Model Number is in alphabetical order.)
(Example) PSS2en-DCEL-DCPS: To apply the unit, combine the DC power supply and the DC electronic load. - As mentioned above, PSS2en has many lineups according to the combination of power supplies and electronic loads. Regarding CD to install PSS2en, it is the same as "PSS2en-ALL" regardless of which lineup is ordered. Users can control power supplies and electric loads using a USB key with a license function for performing only operations in accordance with the lineup ordered.
- Only for the model installed optional digital interface.
- Planning to go on sale in the near future.
- The dedicated adapter needs. For the details, please contact our sales staff.
- Regarding PSS2en-COMS, it is necessary to notify in advance of the power supplies to be used in combination with CO-MS. For more details, please contact our sales staff.
Discontinued models
The following model is no longer available as we have stopped production and sales.
Model No. of PSS2en series | Models supported | |
---|---|---|
PSS2en-ESLD Discontinued | AC Electronic Loads | ESLD series |
Support the operation by the license granted to USB key
You can apply PSS2en in various combinations as it is possible to issue the license for a number of component combinations.
Example of combination
Actuation of DC power supplies in different series
You can actuate two DC power supplies of R4K-36 series and R4K-80 series at the same time by issuing two types of PSS2en license for PSS2en-R4K36 and PSS2en-R4K80.
Actuation in combination of DC power supply and electronic load
You can actuate two DC power supplies of RK-80 series and RK-80 series and DC electronic load of EGD series, at the same time by issuing three types of PSS2en license for PSS2en-RK80, PSS2en-RK, and PSS2en-EGD.
Functions
Operation mode
Constant value mode
It can be operated with the following parameter values constant.
(Compatible with all models of our power supplies and electronic loads listed on "MODELS")Variable parameters (each parameter can be set individually)
- DC power supply, High voltage power supply, Various power supplies via CO series
- DC electronic load
- AC power supply, Bipolar power supply
- Voltage, Current, Operating time
- Voltage, Current, Power, Resistance, Operating time
- Voltage, Frequency, Operating time
Software sequence mode
Keep sending setting values from the computer to change the behavior of our corresponding product.
Various sequences can be set up to 999 steps, depending on the parameters to be varied and the operation pattern.
(Depending on usage conditions, there may be a time lag between when the command is sent from the computer and when the power supply actually operates.)
Variable parameters (each parameter can be set individually)
- DC power supply, High voltage power supply, Various power supplies via CO series
- DC electronic load
- AC power supply, Bipolar power supply
- Voltage, Current, Operating time
- Voltage, Current, Power, Resistance, Operating time
- Voltage, Frequency, Operating time
Hardware programmed output mode (DC power supply is available.)
Pulse pattern and pulse ramp pattern of DC power supply provided optional (*) pulse ramp pattern can be set.
* For more information on these options, please refer to the individual datasheets for each power supply.
It is usable to combine pulse action and ramp action. If combining multi-set functions, it is also possible to actuate program action by using voltage and current values set in memories a, b, and c. It is possible to set repeat count and, of course, continuous operation. It is available in various aspects as it is able to change voltage and current up and down slowly up to the three set values. It is also repeatable.
Hardware sweep (DC power supply is available.)
Sweep items can be set for DC power supplies with -LDe (Pulse ramp pattern) option and main units in TB series.
Hardware waveform mode for bipolar power supply (Only for models included in PSS2en-AMP)
The following intricate waveforms can be generated by setting program items for bipolar power supply main units
Output waveform image from bipolar power supply
Momentary power interruption operating mode
(Only when AC power sources with -LPfl option are connected by PSS2en-DRS or PSS2en-DRJ)
Function with instantaneous interruption time can be set for AC power sources in the DRS series or DRJ series with the -Lpfl option.
Output current integration mode
(Only when DC power supplies with -LIc option are connected by models included in PSS2en-DCPS)
Integrated current value during sequential control operation can be monitored on DC power supplies equipped with -LIc option. (Up to 100 Ah) Also, the integrated current maximum value can be set as the stop condition of the sequential control operation.
It is very useful for purposes such as the management of plating solutions. For more details on these options, please refer to each datasheet of power supplies.
In addition to being introduced here, it is available under various specifications. Please feel free to contact our sales staff for more details.
Example
- Capacitor foil test
- Battery charge/discharge Test
- Hipot testing
Example for sequential control operation
1. Programmed Test Sequence
First, set up communication with Matsusada Precision's Power Supply. Next, select the operating mode and build the automatic test sequence. No programming knowledge is required to build an automated test sequence. You can build an advanced automatic sequence program without in-depth programming knowledge by simply selecting the necessary items and entering numerical values. The number of settable program patterns is max. 16, It is possible to set various test conditions fitted to the target like selection of the operation mode and setting of any protection function, etc.
2. Test Execution Flow
It is possible to the test sequence of each group setup. On the operation display, it is possible to monitor the required information on one screen, such as a program, the status of the thermostatic chamber and the power supply, and voltage/current at testing. Also, when executed in parallel plural groups, it is possible to monitor this status together.
3. Viewing Measured Data and Graphs
It is possible the test data is completed. It is possible to confirm the value of each test sequence, the individual graph, or all items shown in one graph. Also, it is possible to output measured data in CSV style and then sum up or analyze them with the spreadsheet software.
DIRECT CONTROL MODE
It is possible to control directly the objective components to be controlled, such as power supplies. Various controls are possible on one screen, such as output ON/OFF, change in setting parameters such as voltage, record of output value, Confirm status, etc. Since multiple power supplies can be controlled on one screen and individual parameters can be set, it can be used for various applications.
*Models included in PSS2en-ACPS and PSS2en-AMP are not available for control of multiple units.
Different types of interfaces
Automatic control operation is possible at each communication port, such as LAN port, USB (TMC) port, and RS-485, by equipping the power supplies with the -LMi option. It is possible to select the interface according to the usage status and the application of power supplies.
- Installation of VISA (Virtual Instrument Software Architecture) Library necessary to use each communication port.
VISA library is the standard specification of measuring instrument connection software developed by the IVI Foundation.
PSS2en has been performed operation verification with National Instrument NI-VISA(Ver5.4). - For power supplies that can be equipped with -LMi option, please cc our sales staff.
When using LAN or USB(TMC) port in -LMi option models, I data can be recorded at a minimum of 0.1-second intervals per power supply.
In other cases, minimum interval can be set for 0.5 seconds.
CONNECTION EXAMPLE
Easy control of high voltage power supply with one LAN cable
Parallel operation of the R4K-36 units in different sequential programs. Operates in different sequential programs
Control of high voltage power supplies with the CO-HV controllers
Sweeping by using two bipolar power supplies built-in function generator
Test system combined DC power supply and electronic loads
Specifications
Operation environmental
OS * |
Windows 11 (32/64 bit), 10 (32/64 bit), 8.1 (32/64bit), 8 (32/64bit) * We conducted the evaluation of the operating environment on Windows 10 Pro (Version 1909). The other operating systems have been checked, but we cannot guarantee their operation of them. |
---|---|
Language | English |
CPU | Pentium4 or higher grade |
RAM | 1 GB and larger |
HDD | 500 MB and larger free space |
Display | 1024 pixels x 768 pixels and higher resolution |
Protection for software |
1 port or more (Connected USB Security Key is required.) |
- Microsoft and Windows are registered trademarks of Microsoft Corporation in the USA and other countries.
- Other product names are registered trademarks of each company concerned.
- Only when a plural kind of PSS2en is purchased at the same time, it is able to consolidate the USB key to one. For details, please contact our sales staff.
- Only when a plural kind of PSS2en is purchased at the same time, it is able to consolidate USB key to one. For details, please contact our sales staff.
- There are some cases that it does not operate correctly depending on the ROM version installed in our product concerned. We recommend purchasing software and hardware at the same time.
Download
If you are unable to download a file
Please try the following solution.
- Please press Ctrl+F5 to clear the cache of your web browser and try again.
- Please restart your web browser and log in again to try again.
- Please change your web browser to another browser and try again.
- Restart the computer and try again.
- Please try again on a different computer.
-
PSS2en series Datasheet
Date: 2023-10-17 rev. 15
PDF (3,672 KB)
-
PSS2en DCPS Instruction Manual
Date: 2024-4-30 rev 6.7
PDF (2,412 KB)
-
PSS2en DCEL Instruction Manual
Date: 2024-4-30 rev 4.9
PDF (3,030 KB)
-
PSS2en ACPS Instruction Manual
Date: 2024-4-30 rev 5.0
PDF (2,735 KB)
-
PSS2en HVPS Instruction Manual
Date: 2024-4-30 rev 3.0
PDF (2,491 KB)
-
PSS2en AMP Instruction Manual
Date: 2024-4-30 rev 5.5
PDF (3,462 KB)
-
PSS2en CO Instruction Manual
Date: 2024-4-30 rev 5.9
PDF (1,958 KB)
-
PSS2en COMS Instruction Manual
Date: 2024-4-30 rev 1.1
PDF (1,996 KB)
Login Required
-
PSS2en series Datasheet
Date: 2023-10-17 rev. 15
PDF (3,672 KB)
-
PSS2en DCPS Instruction Manual
Date: 2024-4-30 rev 6.7
PDF (2,412 KB)
-
PSS2en DCEL Instruction Manual
Date: 2024-4-30 rev 4.9
PDF (3,030 KB)
-
PSS2en ACPS Instruction Manual
Date: 2024-4-30 rev 5.0
PDF (2,735 KB)
-
PSS2en HVPS Instruction Manual
Date: 2024-4-30 rev 3.0
PDF (2,491 KB)
-
PSS2en AMP Instruction Manual
Date: 2024-4-30 rev 5.5
PDF (3,462 KB)
-
PSS2en CO Instruction Manual
Date: 2024-4-30 rev 5.9
PDF (1,958 KB)
-
PSS2en COMS Instruction Manual
Date: 2024-4-30 rev 1.1
PDF (1,996 KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.