Search waiting | Matsusada Precision

Searching...

X-ray Generator units (X-Ray Sources, X-ray Modules) XWR series (Discontinued)

  • XWR series | X-ray generator unit | Matsusada Precision
  • XWR series | X-ray generator unit | Matsusada Precision
Discontinued

HIGH POWER X-RAY GENERATOR –DUAL UNIT MODULE

  • Twin box
  • X-ray tube voltage: 60kV to 130kV
  • X-ray power: 120W to 260W

HIGH POWER X-RAY MODULE

XWR series is the 2-unit type X-ray module with a high-stability power supply and X-ray tube. Compatible with high power and compactness by our original thermal design technologies. Suitable for integration into the measurement equipment.

FEATURES AND BENEFITS

  • Wide lineup, 60 kV to 130 kV/120 W to 260 W
  • Continuous operation is available.
  • Stable X-ray output
  • User-friendly operation

APPLICATIONS

Models

Model Anode voltage Beam current Max Power Focal spot size Radiation angle Window material Operation Dimension
W x D x H [inch (mm)]
MAX MIN Controller unit X-ray unit
XWR120-60 60 kV 10 kV 2 mA 120 W 1 mm 20° Glass Continuous 8.35 x 12.99 x 5.51
(212 x 330 x 140)
5.12 x 10.75 x 6.97
(130 x 273 x 177)
XWR240-80 80 kV 30 kV 3 mA 240 W 1mm 60° 18.98 x 24.02 x 5.24
(482 x 610 x 133)
8.11 x 18.90 x 8.96
(206 x 480 x 225)
XWR200-100 100 kV 30 kV 2 mA 200 W 1 mm 60° 18.98 x 24.02 x 5.24
(482 x 610 x 133)
8.11 x 18.90 x 8.96
(206 x 480 x 225)
XWR260-130 130 kV 30 kV 2 mA 260 W 1 mm 60° 18.98 x 24.02 x 6.97
(482 x 610 x 177)
8.11 x 18.90 x 8.96
(206 x 480 x 225)

Specifications

For details, download the datasheet below.

FAQ for performance of X-Ray Inspection System
X-Ray Inspection System FAQ

Options

-L(200V)

200 Vac to 240 Vac 50/60 Hz single phase input
* When ordering, suffix the above option number to the model number.

Dimensions

For details, download the datasheet below.

Download

If you are unable to download a file

Please try the following solution.

  1. Please press Ctrl+F5 to clear the cache of your web browser and try again.
  2. Please restart your web browser and log in again to try again.
  3. Please change your web browser to another browser and try again.
  4. Restart the computer and try again.
  5. Please try again on a different computer.

Login Required

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Information on related articles in Technical Knowledge

X-ray Power Supplies and X-ray Generators

Search for related to X-ray Power Supplies and X-ray Generators