Electronic Loads Selection Chart
Electronic Load Selection Chart What is an electronic load, •A load device that uses semiconductors to change current, voltage, resistance, or power. •Electronic loads require less space, heat dissipation, and calculation than resistive loads. •Electronic loads include DC electronic loads, AC electronic loads, and regenerative electronic loads.
Matsusada Precision offers a wide range of models, from benchtop-size DC electronic load devices to rack-size regenerative electronic loads. Boosters can expand some models. The devices are also equipped with communication functions, so they can be used for multi-channel systemization, etc.
DC Electronic Load / Regenerative Electronic Load (Bidirectional Power Supply) Type
Types | DC Electronic Loads | Regenerative Electronic Loads (Bidirectional Power Supplies) | ||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Series | EGS | EGD | EZD | EW | PBR | PBRM | ||||||||
Image (model) |
EGS75W-18V | EGS75W-36V | EGS75W-60V | EGD150W-150V | EGD200W-150V | EGD300W-150V | EZD650V-330W | EZD650V-1000W | EZD650V-2000WB (Booster) | EW150V-1200W | EW150V-2400W | EW150V-2400WB (Booster) | 19 models | 45 models |
Load power | 75W | 75W | 75W | 150W | 200W | 300W | 330W | 1000W | 2000W | 1200W | 2400W | 2400W | 5KW,10kW,15kW, Max. 150kW |
30kW to 150kW |
Voltage Range | 18V | 36V | 60V | 150V | 150V | 150V | 650V | 650V | 650V | 150V | 150V | 150V | 80V to 1500V | 80V to 1500V |
Current | 10A | 5A | 2A | 30A | 30A | 60A | 16.5A | 50A | 100A | 240A | 480A | 480A | 20A to 360A | 60A to 3600A |
Range | - | - | - | - | - | - | High/Low | High/Low | - | High/Low | High/Low | - | - | - |
CC mode | - | - | ||||||||||||
CR mode | - | - | ||||||||||||
CV mode | - | - | - | - | - | |||||||||
CP mode | - | - | - | - | - | - | - | - | ||||||
Automatic mode | - | - | - | - | - | - | - | - | - | - | ||||
CC and CR mode | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
CC and CV mode | Option | Option | Option | - | - | - | - | - | - | - | - | - | ||
CR and CV mode | - | - | - | - | - | - | - | - | - | - | - | - | ||
CP and CV mode | - | - | - | - | - | - | - | - | - | - | - | - | ||
Short mode | - | - | - | - | - | - | - | - | - | - | ||||
VI mode | - | - | - | - | - | - | - | - | - | - | - | - | ||
Master/Slave |
16 units |
16 units |
16 units |
16 units |
16 units |
16 units |
4 units |
4 units |
- |
4 units |
4 units |
- |
10 units |
- |
External Analog remote control | - | - | - | - | - | |||||||||
LAN | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | - | - | ||||
USB | Option or Adaptor | Option or Adaptor | Option or Adaptor | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | - | - | ||||
RS-232C | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | Additional adapter | - | Additional adapter | Additional adapter | - | Option | Option | |
Sequence | - | - | - | - | - | - | - | - | ||||||
Features | Compact, benchtop slim type, dedicated shelf for multiple channels | Compact, benchtop | Multifunctional, half-rack size, 19" rack size, up to 9kW with booster | Intelligent, high-power, expandable up to 12 kW with booster | Compact, high-power with regenerative function, energy recovery | Regenerative, high-power, 19" rack type | ||||||||
Series | EGS | EGD | EZD | EW | PBR | PBRM |