Search waiting | Matsusada Precision

Searching...

  • DOD series | Bipolar power supply (Low Voltage Amplifiers) | Matsusada Precision
  • DOD series | Bipolar power supply (Low Voltage Amplifiers) | Matsusada Precision

Discontinued

Ultra-low ripple noise bipolar power supplies for the exclusive use of the electromagnet

High stability, High accuracy, Low ripple noise

DOD series is no longer available as we stopped the production and sales of this model in January 2021. Meanwhile, we support.

High-performance bipolar power supplies for exclusive use of the electromagnet

DOD series are the ultra-low ripple noise bipolar power supplies for the exclusive use of the electromagnet. From the wide lineup(the range of output current ±10 A to ±100 A), You can choose the most suitable model for the characteristics of your electromagnet.
Special attention has been paid to designing the internal circuits of the power supply to be symmetrically placed, which helps reduce a great amount of common-mode noise, despite the amazing small footprint of the equipment.
DOD series is the most suitable power supply for an electromagnet as a high-stability and low-noise current supply source.

Features

Wide lineup
You can choose the most suitable model from the wide lineup of up to ±120 V from ±10 V.
The display of DC output voltage and current value
DC output voltage and current value are displayed on the 3.5-digit digital meter on the front panel.
Compact and Lightweight
DOD series is designed to pursue the possible smallest footprint and lightweight, resulting in user's great space-saving.
Useful protection function
Protections such as for overvoltage, overcurrent, output short circuit, cooling fan error and power failure are standardly equipped to DOD series.
Digital control
Digital control via LAN (Ethernet) is available.

Applications

Models

Please feel free to ask us about the specifications except the list below.

Model Output Input
Voltage [V] Current [A] Power [W] Standard -L(400V) option
Voltage Current (@200V) Voltage Current (@400V)
DOD10-100 ±10 ±100 1000 AC200 V
to 240 V
±10%

3-phase
6 A typ AC400 V
±10%

3-phase
3 A typ
DOD20-30 ±20 ±30 600 5 A typ
DOD40-30 ±40 ±30 1200 6 A typ
DOD60-20 ±60 ±20 1200
DOD80-10 ±80 ±10 800
DOD120-20 ±120 ±20 2400 12 A typ 6 A typ

Functions

About protection function

OVP (Overvoltage protection)
Output voltage is limited not to exceed approx. 120% of the rated voltage in an emergency case, thus protecting the load.
OCP (Overcurrent protection)
Output current is limited not to exceed approx. 120% of the rated current in an overload case, thus protecting the power supply and load.

Explanation of functions

Front

Dimensions inch (mm) /Explanation of functions Front

Rear

Dimensions inch (mm) /Explanation of functions Rear
  1. Emergency stop button
  2. OUTPUT ON switch
  3. OUTPUT OFF switch
  4. Output voltage/current meter
  5. "Local" button
  6. "Remote" button (control via Ethernet)
  7. Button for setting output current
  8. LED for displaying the state of power receiving
  9. POWER switch
  10. Terminal for monitoring output current
  11. Icon-in terminal
  12. LAN (Ethernet) connector
  13. Output terminal
  14. Terminal for status signal and interlock
  15. Terminal for monitoring output voltage
  16. Terminal for monitoring the preset value of output current
  17. Terminal 2 for monitoring output current
  18. AC input terminal

Specifications

For details, download the datasheet below.

Options

-L(400V)

For the change of input voltage and current.

-LTc

Temp. stability of output current; 5 ppm/℃

-LEp

Control by EPICS
(Experimental Physics and Industrial Control System)

How to order

To order, please add the above option number to the model number.

[Example] DOD10-100-LEpTc (Alphabetical order)

Dimensions

For details, download the datasheet below.

Tech Notes

Capacitive Load

When a capacitive load is more than 100 pF (including a stray capacitance of output wire), the resonance in the output may occur. In that case, install 100-ohm (@0.1 μF) to 1000-ohm (@1000 pF) of high voltage resistance in the output in series. Please note that the frequency band will be limited as the formula written in the right figure when an amplifier is used with a capacitive load.
In addition, when an amplifier is used for the use such as a corona discharge, the current which is higher than rating will flow and it will affect the amplifier badly. In this case, as well as the time to use an amplifier with a capacitive load, please install the output resistance and limit the current.

* Please avoid continuous inputting of high frequency signal which reduces output frequency of an amplifier. An amplifier will be broken because of increase of internal loss.

This image explains frequency band when a capacitive load is connected.

Read more

Download

If you are unable to download a file

Please try the following solution.

  1. Please press Ctrl+F5 to clear the cache of your web browser and try again.
  2. Please restart your web browser and log in again to try again.
  3. Please change your web browser to another browser and try again.
  4. Restart the computer and try again.
  5. Please try again on a different computer.

Login Required

In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.

Bipolar power supplies (Low Voltage Amplifiers)

Search for related to Bipolar power supplies (Low Voltage Amplifiers)