Benchtop
DC Electronic Loads
- Operational Voltage range:
1.5 Vdc to 150Vdc - Load current: 30A to 60A
- Load power:
150W, 200W, and 300W - World wide input
Compact Size and High Power
EGD series is ideal for DC electronic loads for testing batteries, power supplies and power converters, aging tests and so on.
They are able to build the charge and discharge system combined with our DC power supplies REK series or RK series with LAN, USB, RS-232C, RS-485, or GPIB interface.
FEATURES
- Five units can be placed into a 19-inch Rack of 3U size. (150 W and 200 W models)
- They are operable in two modes of Constant Current (CC) and Constant Resistance (CR).
- Worldwide input is applicable to any commercial electric power source in the world.
- Package control to 16 units is possible.
APPLICATIONS
- Evaluation of switching power supply
- Evaluation of DC/DC converter
Models
Model | Rated voltage | Rated current | Maximum load power [W] |
---|---|---|---|
EGD150W-150V | 150 V | 30 A | 150 W |
EGD200W-150V | 30 A | 200 W | |
EGD300W-150V* Coming soon | 60 A | 300 W |
* The load time of this model is different from other models, so please contact our sales office for details.
Functions
EGD series is light and compact!
Maximum load capacity 200W is realized
At the evaluation test of the compact battery, which is not so large, we also hope to place the load device compactly.
EGD series are just fitted with the best electronic load for such a situation.
They can be utilized in Stand-Alone with operation on the front panel.
They can be utilized as DC electronic load of multi-channels
If the dedicated adapter (Sold separately) is used, a maximum of Five units of EGD series are placed in a rack of 19-inch and they can be utilized as a DC electronic load with multi-channel.
The Following combination is able.
150 W and 200 W Models | 300 W Model | ch No. |
---|---|---|
5 units | - | 5 ch |
4 units | - | 4 ch |
3 units | - | 3 ch |
2 units | 1 units | 3 ch |
1 units | 1 units | 2 ch |
- | 2 units | 2 ch |
Digital interface
In addition to digital control via USB, LAN, RS-232C, RS-485, or GPIB collective control is enabled in the master/slave operation.
Master/Slave control
The operations of up to 16 EG devices can be controlled from the master unit. (Not for increasing current by parallel connection)
Remote control
Switching Remote/Local
Model | External Relay | TTL |
---|---|---|
remote | short | LOW |
local | open | HIGH |
Load control and operation modes can be changed with relay or TTL signal.
Load Control
Load Resistance/ Load Current |
Control Voltage | R |
---|---|---|
MIN to MAX | 0 to 10 Vdc Input impedance 500 kΩ |
0 to approx. 10 kΩ |
Voltage/Current Monitor
Input Voltage/current 0 to Max. |
0 to 10 Vdc Output Impedance 1 kΩ |
0 to 10 Vdc Output Impedance 1 kΩ |
---|
Status Output
FLT...ON at the abnormal conditions
(ON at statuses of OCP, OVP, OPP, UVP, and OTP)
- COMMON is floating at open collector output.
- Withstand Voltage: 30 Vdc, Sink Current: ≤ 5 mA
Load ON/OFF
Load | Relay | Open collector |
---|---|---|
ON | Short | VCE ≤ 0.4 V |
OFF | Open | VCE ≥ 2 V |
Sink current: 1 mA
Specifications
Options
- -L(Mc0.5), -L(Mc0.15): Changing cable length
- The Length of the CO-M cable (refer to page 4) is 0.5 meters or 0.15 meters, respectively. (Please select either one.)
How to Order
When ordering, add Option No. to Model No.
Example: EGD150W-150V-L(Mc0.5)
Accessories
- AC Input Cable
-
Standard CABLE TYPE1 125 V / 10 A 2.5 meters
Fixed lengthSold separately CABLE TYPE3 250 V / 10 A 2.5 meters
Fixed lengthSold separately CABLE TYPE4 250 V / 10 A 2.5 meters
Fixed length
- Digital interface port
-
To use Matsusada Precision's digital interface, you need to prepare a digital interface adapter separately. The following interface adapters are available according to your controller port.
- CO-E32m: LAN Adapter
- CO-U32m: USB Adapter
- CO-MET2-9: RS-232C (9 pin) Adapter
- CO-MET2-25: RS-232C (25 pin) Adapter
- CO-MET4-25: RS-485 (25 pin) Adapter
- CO-G32m: GPIB Adapter (Discontinued in December 2028)
For details, refer to CO/USB series
Dimensions
Download
If you are unable to download a file
Please try the following solution.
- Please press Ctrl+F5 to clear the cache of your web browser and try again.
- Please restart your web browser and log in again to try again.
- Please change your web browser to another browser and try again.
- Restart the computer and try again.
- Please try again on a different computer.
-
EGD series Datasheet
Date: 2024-05-29 rev.15
PDF (2,275 KB)
-
How to Use DC Power Supplies
Date: 2024-03-05 rev. 08
PDF (1,467 KB)
-
DC Electronic Load Selection Guide
Date: 2024-5-20 rev.04
PDF (6,594 KB)
-
EGD series Basic Instruction Manual
Date: 2020-10-12 rev 0.1
PDF (415 KB)
-
EGD series Instruction Manual
Date: 2020-10-12 rev 1.2
PDF (2,269 KB)
-
EGD series Outline Drawing (DXF, PDF)
Date: 2024-07-25
ZIP (875 KB)
Login Required
-
EGD series Datasheet
Date: 2024-05-29 rev.15
PDF (2,275 KB)
-
How to Use DC Power Supplies
Date: 2024-03-05 rev. 08
PDF (1,467 KB)
-
DC Electronic Load Selection Guide
Date: 2024-5-20 rev.04
PDF (6,594 KB)
-
EGD series Basic Instruction Manual
Date: 2020-10-12 rev 0.1
PDF (415 KB)
-
EGD series Instruction Manual
Date: 2020-10-12 rev 1.2
PDF (2,269 KB)
-
EGD series Outline Drawing (DXF, PDF)
Date: 2024-07-25
ZIP (875 KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.