Optimum Structure for Matsusada Power Supplies
RMO series holds Matsusada Precision's benchtop power supplies and digital communication adaptors to install a 19-inch rack.
The RMO series, specially designed to install our products, offers easy installation in a 19-inch rack and requires no thermal solution.
FEATURES AND BENEFITS
- Special design for perfect fit
- Special cooling structure for stable product performance *1
- Single AC cable combining powers of the forced cooling fan and AC supply (optional).
- Rack cabinet models: CAB series and RAC series of 19-inch rack mount types *2
- Note that the suction temperature of the power supply should be within the operating temperature.
Increasing the temperature by 10 degrees will halve the service life of the product. - Feel free to contact us for details.
Models
Model | Compatible model (example) |
Height [inch (mm)] |
Accommodation (example) |
Specifications |
---|---|---|---|---|
RMO-44H-HALF | REKJ PVCEJ | 1.73 (44) |
|
Dimensions |
RMO-133H-RK |
R4K-36
R4K-80
RK-80
EGS CD (models of 36 W or less) |
5.22 (132.5) |
|
Dimensions |
RMO-133H-RK2 | Dimensions | |||
RMO-133H-RK3 | Dimensions | |||
RMO-133H-RK400 |
RK
PZJR
EQ
TB CO |
|
Dimensions | |
RMO-133H-DRJ |
DRJ
DRS
DJOP
DJOPF CO |
|
Dimensions | |
RMO133H-EPR |
EGD
EPR
CO
CD (models of 48 W or more) |
|
Dimensions | |
RMO-133H-CO | CO | 5.22 (132.5) |
|
Dimensions |
RMO-177H-R4G | R4G/R4GN R4GT R4GE | 6.97 (177) |
|
Dimensions |
RMO-150H-B | ES | 5.87 (149) |
|
Dimensions |
RMO-150H-EJC | EJC |
|
Dimensions |
Model | Compatible model (example) |
Height [inch (mm)] |
Specifications |
---|---|---|---|
RMO-88H | General | 3.31(88) | Dimensions |
RMO-133H | 5.22(132.5) |
- * When putting it away in a 19-inch rack, please establish a space of more than 0.06 inches (1.5 mm) in the lower part for prevention of interference.
- * When attaching the power supply to the RMO series, the installation screws of the plastic feet for the unit are used for mounting.
- * As CO series has no plastic feet, use the attached screws for fixing.
Specifications
RMO-44H-HALF
The RMO-44H-HALF is a rack mount shelf for up to two REKJ and PVCEJ half-rack width power supplies.
It can be installed in 19-inch racks with EIA standard 1U height 1.75-inch (44.45 mm) and JIS standard 1J height 1.97-inch (50 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
- When installing in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
- In the case of a single unit, it should be mounted on either the left or right side. It cannot be mounted in the center.
Additional products
- Blank panel
RMO-133H-RK Up to 10 units store, AC fan included, wiring required for each.
The RMO-133H-RK is a rack-mount shelf that can accommodate up to 10 units of the P4KF-80 series or other slim power supplies measuring 1.38-inch (35 mm) wide and 4.88-inch (124 mm) high. It is equipped with an AC fan, so there is no need to worry about heat dissipation.
It can be installed in 19-inch racks with EIA standard 3U height .22-inch (132.6 mm) and JIS standard 3J height 5.91-inch (150 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Specification |
Input voltage/current 100 V (100 Vac to 120 Vac, 50 Hz/60 Hz) 0.4 A typical * The AC input voltage for the power supply to be installed and of the forced cooling fan |
|
Accessories |
|
- Although the design takes airflow into consideration, the actual temperature during operation shall be verified by the user.
- When in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be install installing ed using only the front panel screws.
Optional item
- -L(230V)
-
The AC input voltage is 230 V of the AC input voltages for the power supply to be installed and of the forced cooling fan 200 V (200 Vac to 240 Vac, 50 Hz/60 Hz) 0.2 A typical (optional).
Additional products
- Blank panel
RMO-133H-RK2 Up to 10 units store, AC fan included, additional AC distribution cable available
The RMO-133H-RK2 is a rack mount shelf that can accommodate up to 10 units of the P4KF-80 series or other slim power supplies measuring 1.38-inch (35 mm) wide and 4.88-inch (124 mm) high. The rack mount shelf is equipped with an AC fan so there is no need to worry about heat dissipation. The AC power distribution circuit is mounted, and the AC connecting harness (additional products) greatly reduces wiring hassles.
It can be installed in 19-inch racks with EIA standard 3U height 5.22-inch (132.6 mm) and JIS standard 3J height 5.91-inch (150 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
|
Specification |
Input voltage/current 100 V (100 Vac to 120 Vac, 50 Hz/60 Hz) 0.4 A typical (fan current only). * The AC input voltage for the power supply to be installed and of the forced cooling fan |
- Although the design takes airflow into consideration, the actual temperature during operation shall be verified by the user.
- A single AC cable is attached to the model so that AC input lines of the power supplies and forced air cooling fans can be put together.
AC connecting harness is needed separately as the accessory. Please see “ADDITIONAL PRODUCTS” - When in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be install installing ed using only the front panel screws.
Optional item
- -L(230V)
-
The AC input voltage is 230 V of the AC input voltages for the power supply to be installed and of the forced cooling fan 200 V (200 Vac to 240 Vac, 50 Hz/60 Hz) 0.2 A typical (fan current only) (optional).
Additional products
- Blank panel
- AC connecting harness
-
This cable supplies electrical power from the rack mount shelf (RMO-133H-RK2) to the power supply.
- CABLE RM-80W TYPE For RK-80, R4K-80, EGS, and CD series (10 pcs/set)
- CABLE RM-36W TYPE For previous type R4K-36 series (with coupler IEC60320 C5 attached) (10 pcs/set)
- CABLE RM-36W2 TYPE For R4K-36 series (with coupler IEC60320 C13 attached). (10 pcs/set)
RMO-133H-RK3 Up to 10 units store, AC fan and switch included, additional AC distribution cable available
The RMO-133H-RK3 is a rack mount shelf that can accommodate up to 10 units of the P4KF-80 series or other low-profile power supplies measuring 1.38-inch (35 mm) wide and 4.88-inch (124 mm) high. The rack mount shelf is equipped with an AC fan so there is no need to worry about heat dissipation. The AC power distribution circuit is mounted, and the AC connecting harness (additional products) greatly reduces wiring hassles. The RMO-133H-RK3 also has an AC switch on the front panel, so the FAN and onboard power supply can be controlled on/off at the front.
It can be installed in 19-inch racks with EIA standard 3U height 5.22-inch (132.6 mm) and JIS standard 3J height 5.91-inch (150 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
|
Specification |
Input voltage/current 100 V (100 Vac to 120 Vac, 50 Hz/60 Hz) 0.4 A typical (fan current only). * The AC input voltage for the power supply to be installed and of the forced cooling fan |
- Although the design takes airflow into consideration, the actual temperature during operation shall be verified by the user.
- A single AC cable is attached to the model so that AC input lines of the power supplies and forced air cooling fans can be put together.
The model is also equipped with a POWER switch on the front panel, which enables turn on/off all the power of up to 10 units at once. AC connecting harness is needed separately as the accessory. Please see “ADDITIONAL PRODUCTS” - When in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be install installing ed using only the front panel screws.
Optional item
- -L(230V)
-
The AC input voltage is 230 V of the AC input voltages for the power supply to be installed and of the forced cooling fan 200 V (200 Vac to 240 Vac, 50 Hz/60 Hz) 0.2 A typical (fan current only) (optional).
Additional products
- Blank panel
- AC connecting harness
-
This cable supplies electrical power from the rack mount shelf (RMO-133H-RK3) to the power supply.
- CABLE RM-80W TYPE For RK-80, R4K-80, EGS, and CD series (10 pcs/set)
- CABLE RM-36W TYPE For previous type R4K-36 series (with coupler IEC60320 C5 attached) (10 pcs/set)
- CABLE RM-36W2 TYPE For R4K-36 series (with coupler IEC60320 C13 attached). (10 pcs/set)
RMO-133H-RK400
The RMO-133H-RK400 is a rack-mount shelf that can accommodate up to six benchtop power supplies with a height of 4.88-inch (124 mm) and a width of 2.76-inch (70 mm) to 8.27-inch (210 mm), such as the TB series. You can also mount the CO series of communication adapters together. It can be installed in 19-inch racks with EIA standard 3U height 5.22-inch (132.6mm) and JIS standard 3J height 5.91-inch (150 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
- As CO series has no plastic feet. Fix the product with fixing screws (ADDITIONAL PRODUCTS).
- The product is also available for CO series in combination with applicable power supplies. For details, contact our sales representatives.
- When installing in a 19-inch rack, be sure to use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
- Note that the RK series, PZDR series, and TB series with handles exceed 5.24-inch (133 mm) in height.
Additional products
- Blank panel
- CO series mounting screw-A
-
Using this screw set, you can mount our CO series digital communication adapters (11 units) on the RMO-133H-RK400
- Spacer (Ø: 3 x 5)
- Pan-head machine screw (M3 x 6)
- Flat head machine screw (M3 x 10) 11 pieces each of 11 units
RMO-133H-DRJ
The RMO-133H-DRJ is a rack mount shelf that can accommodate up to three power supplies with a height of 4.72-inch (124 mm) and a width of 5.51-inch(140 mm) or 8.27-inch (210 mm), such as the SRS and DRJ series of AC power sources and the DJOPF bipolar power supply. Three DRJ series units can be accommodated to provide three-phase alternating current (AC) output in a 3U height. You can also mount the CO series of communication adapters together.
It can be installed in 19-inch racks with EIA standard 3U height 5.22-inch (132.6 mm) and JIS standard 3J height 5.91-inch (150 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
- As CO series has no plastic feet. Fix the product with fixing screws (ADDITIONAL PRODUCTS).
- The product is also available for CO series in combination with applicable power supplies. For details, contact our sales representatives.
- Please note that DRJ series, DRS series, and DJOPF series with handles exceed 5.24 inches (133 mm) in height. If the handles are unnecessary, select DRJ-LNh.
- The product is also available for CO series in combination with applicable power supplies. For details, contact our sales representatives.
- When installing in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
Additional products
- Blank panel
- CO series mounting screw-A
-
Using this screw set, you can mount our CO series digital communication adapters (11 units) on the RMO-133H-RK400
- Spacer (Ø: 3 x 5)
- Pan-head machine screw (M3 x 6)
- Flat head machine screw (M3 x 10) [11 pieces each of 11 units]
RMO-133H-EPR
The RMO-133H-EPR is a rack mount shelf that can accommodate the EPR series of high-voltage power supplies, the EGD series of electronic loads, and the CD series of battery-ju discharge power supplies. You can also mount the CO series of communication adapters together.
It can be installed in 19-inch racks with EIA standard 3U height 5.22-inch (132.6 mm) and JIS standard 3J height 5.91-inch (150 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
- As CO series has no plastic feet. Fix the product with fixing screws (ADDITIONAL PRODUCTS).
- It is available as a compact charge/discharge system in combination with EGD series and RK series DC power supply (in 400 W, 800 W, and 1200 W types). As for the number of units available in the combination, contact our sales staff.
- The product is also available for CO series in combination with applicable power supplies. For details, contact our sales representatives.
- When installing in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
Additional products
- Blank panel
- CO series mounting screw-B
-
Using this screw set, you can mount our CO series digital communication adapters (11 units) on the RMO-133H-EPR
- Pan head machine screw: M3 x 6 (22 pieces)
RMO-133H-CO
The RMO-133H-CO is a rack mount shelf exclusively for the CO series of interface and conversion adapters for communication. Up to 11 units can be mounted.
It can be installed in 19-inch racks with EIA standard 3U height 5.22-inch (132.6 mm) and JIS standard 3J height 5.91-inch (150 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
- As the CO series has no plastic feet, use the attached screws for fixing.
- When installing in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
Additional products
- Blank panel
RMO-177H-R4G
The RMO-177H-R4G is a rack mount shelf exclusively for the R4G/R4GN and R4GT series of series regulator type regulated DC power supplies. A cooling FAN is mounted on the bottom.
It can be installed in a 19-inch rack with EIA standard 4U height 6.97-inch (177 mm) and JIS standard 3J height 7.87-inch (200 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
has the forced convection cooling system, and the FAN attached to the rackmount is not always required. |
|
Accessories |
|
|
Specification |
Input voltage/current 100 V (100 Vac to 120 Vac, 50 Hz/60 Hz) 0.4 A typical (fan current only). * The AC input voltage for the power supply to be installed and of the forced cooling fan |
- Although the design takes airflow into consideration, the actual temperature during operation shall be verified by the user.
- Make 3.94 inches (100 mm) or more room both on the top and bottom or install forced cooling system. Note that the R4G series with handles exceeds the height of the rack mount.
- When installing in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
Optional item
- -L(230V)
-
The AC input voltage is 230 V of the AC input voltages for the power supply to be installed and of the forced cooling fan (200 Vac to 240 Vac, 50 Hz/60 Hz) 0.2 A typical (fan current only) (optional).
Additional products
- Blank panel
RMO-150H-B
The RMJ-150H-B is a rack mount shelf exclusively for the ES series of high voltage power supplies.
It can be mounted on a 19-inch rack with JIS standard 3J height 5.91-inch (150 mm) or EIA standard 4U height 6.97-inch (177.0 mm).
Mmountable models |
|
|
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
- Make 3.94 inches (100 mm) or more room both on the top and bottom or install a forced cooling system.
- When installing in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
Additional products
- Blank panel
RMO-150H-EJC
The RMJ-150H-EJC is a rack mount shelf exclusively for the EJC series of high voltage power supplies for electrostatic chucks. Up to two units can be mounted.
It can be mounted on a 19-inch rack with JIS standard 3J height 5.91-inch (150 mm) or EIA standard 4U height 6.97-inch (177.0 mm).
Mmountable models | ||
---|---|---|
Accommodation <Example> |
|
|
Accessories |
|
- When installing in a 19-inch rack, use support angles or other reinforcing hardware. It cannot be installed using only the front panel screws.
Additional products
- Blank panel
RMO-88H/RME-133H
The RMO-88H is a general-purpose rackmount adapter that can be installed in an EIA standard 19-inch rack with a height of 2U 3.47-inch (88.1 mm).
The RMO-133H is a general-purpose rackmount adapter that can be installed in an EIA standard 19-inch rack with a height of 3U 5.22-inch (132.6 mm).
Mmountable models | General use for other applications | |
---|---|---|
Accommodation <Example> |
- | |
Accessories | - |
- As the CO series has no plastic feet, Fix the product with fixing screws (ADDITIONAL PRODUCTS).
- For details about the available models, see the DXF diagram data.
Regarding the information about the combination of the products, refer to the DXF diagram data on our website. As for the fanless designed power supplies (R4K, R4G, etc.) or electronic loads (EGS, etc.), the use of the product could have an adverse impact on the service life due to lacking sufficient space or no cooling fan. Please see each instruction manual for the detailed information. In the meantime, if you have any questions about the product, feel free to contact us.
Options
- -L(230V)
-
The AC input voltage is 230 V of the AC input voltages for the power supply to be installed and for the forced cooling fan (200 Vac to 240 Vac, 50 Hz/60 Hz).
(RMO-133H-RK/RK2/RK3, RMO-177H-R4G)
ADDITIONAL PRODUCTS
Blank panel
Panel to hide the clearance caused by mounting products less than accommodation on the rack mount shelf. Depending on the kind or number of power supplies and controllers, the base of the RMO series may sag a little bit. It will be lessened by the equipped blank panel.
- Blank Panel for RMO-44H-HALF
-
Model Panel width Compatible shelf BPA-44H-212W 8.35 inches
(212 mm)
- Blank Panel for RMO-133H/RMO-177H
-
Model Panel width Compatible shelf BPA-124H-35W 1.38 inches
(35 mm)BPA-124H-70W 2.76 inches
(70 mm)BPA-124H-84W 3.31 inches
(84 mm)BPA-124H-105W 4.13 inches
(105 mm)BPA-124H-140W 5.51 inches
(140 mm)BPA-124H-210W 8.27 inches
(210 mm)<Example of use> Rack mount shelf: RMO-133H-RK400 <Example of use> Rack mount shelf: RMO-133H-CO
- Blank panel for RMO-150H
-
Model Panel width Compatible shelf BPA-140H-35W 1.38 inches
(35 mm)BPA-140H-70W 2.76 inches
(70 mm)BPA-140H-105W 4.13 inches
(105 mm)BPA-140H-135W 5.31 inches
(135 mm)BPA-140H-212W 8.35 inches
(212 mm)<Example of use> Rack mount shelf: RMO-150H-B
Dimensions
Download
If you are unable to download a file
Please try the following solution.
- Please press Ctrl+F5 to clear the cache of your web browser and try again.
- Please restart your web browser and log in again to try again.
- Please change your web browser to another browser and try again.
- Restart the computer and try again.
- Please try again on a different computer.
-
RMO series Datasheet
Date: 2024-09-19 rev.20
PDF (2,406 KB)
-
RMO series Instruction Manual
Date: 2023-4-18 rev.1.6
PDF (3,527 KB)
Login Required
-
RMO series Datasheet
Date: 2024-09-19 rev.20
PDF (2,406 KB)
-
RMO series Instruction Manual
Date: 2023-4-18 rev.1.6
PDF (3,527 KB)
In this website, we provide only the latest version of information including instruction manuals as of our products. Therefore, the newest versions of manuals on the website might be not same as the ones of products you purchased in the past.